HRV & ERV Cleaning & Maintenance

Complete HRV/ERV service: filters, heat-exchange core, fans, condensate path and connected ducting — restoring the fresh-air performance the unit was built for.

Most homes built in BC over the past couple of decades have an HRV or ERV — a ventilation unit that runs more hours per year than almost any other appliance in the home, and gets serviced less than any of them. When filters load up and the core coats with dust, the unit keeps running but moves less and less air. The home gets stuffier, windows condensate more, and the energy recovery the unit was designed for quietly disappears.

A proper service goes well beyond rinsing the filters. We open the unit fully: filters cleaned or replaced, the heat-exchange core removed and washed, fan wheels cleaned (a thin coat of dust on fan blades measurably cuts airflow), the condensate pan and drain checked, and the exterior intake and exhaust hoods cleared — bird nests and lint mats at the hoods are more common than you’d think. Where the connected ducting is accessible, it gets cleaned too.

Condos and building-wide HRV programs

In newer condo buildings, each suite often has its own compact HRV — hundreds of identical units on one roof-to-suite ventilation design, most untouched since occupancy. We service these suite by suite as part of coordinated building programs, pairing naturally with bathroom exhaust and dryer exhaust service in the same visit.

After service you’ll know the unit runs at proper airflow, and when it should be looked at next — typically a filter check every three to six months and a full service annually.

What this service includes

  • Filter cleaning or replacement
  • Heat-exchange core removal and cleaning
  • Fan and fan-wheel cleaning
  • Condensate pan and drain check
  • Accessible connected ducting cleaned
  • Exterior intake and exhaust hood cleaning
  • Operation and airflow check after service

Common questions

What is an HRV?

A heat recovery ventilator (HRV) continuously exchanges stale indoor air with fresh outdoor air while transferring heat between the two airstreams, so fresh air arrives without losing all the warmth you have paid for. Most newer BC homes and condos have one. Its filters, core and connected ducting need regular cleaning to keep airflow at design levels.

What is an ERV, and how is it different from an HRV?

An energy recovery ventilator (ERV) works like an HRV but also transfers moisture between the incoming and outgoing airstreams, which helps manage humidity. From a maintenance perspective the two are similar: filters, the core, condensate paths and connected ducting all need periodic service.

How often should an HRV or ERV be serviced?

Filters typically need attention every three to six months, and a fuller service — core, fans, condensate path and accessible ducting — is generally worthwhile annually. If a unit has never been serviced, the first visit usually makes a noticeable difference to airflow.

More questions? See the full FAQ.